 È£¾Èºí·°¿¬°áüÀÎ,È£¾Èºí·°Ã¼ÀÎ,È£¾Èºê·°¿¬°áüÀÎ,È£¾Èºê·°Ã¼ÀÎ,½Å»ýÈ£¾Èºí·°¿ëüÀÎ

¿À¼º»ê¾÷ > 9. ·ÎÇÁºÎ¼Ó·ù > ¼ÒÄÏ 3¿ÍÀ̾î¶ô »ó¼¼º¸±â

  3¿ÍÀ̾î¶ô

¿µ¹®À̸§

:

 wire lock

»óÇ°ÄÚµå

:

 509314

Á¦Á¶Á¶

:

 usa

¾÷Á¾

:

 9._·ÎÇÁºÎ¼Ó·ù/¼ÒÄÏ

  

3¿ÀǼÒÄÏ-...

3Å©·ÎÁî¼Ò...

3¹«¾î¸µ¼Ò...

3Å©·ÎÁî ¼Ò...

3¿ÀǼÒÄÏ...

3¿ÀǼÒÄÏ...

3¿ÍÀ̾î¶ô  

1¢À Socket Lock

General Kits

Socket Size

1¢À 250cc

mm

inch

CCs

2¢À 500cc

6~7

1/4"

9

3¢À 1,000cc

8~10

5/16"~3/8"

17

4¢À 2"~2 5/8"

11~13

7/16"~1/2"

35

5¢À 2 3/4"~3 3/8"

14~16

9/16"~5/8"

52

6¢À 3 1/2"~4"

19

3/4"

86

item No

Kit Size

Packing

22

7/8"

131

SOL010

250cc

9

26

1"

164

SOL020

500cc

8

29

1 1/8"

210

SOL030

1,000cc

4

32~35

1 1/4"~1 3/8"

361

SOL040

2" ~ 2 1/8"

each

37

1 1/2"

426

SOL050

2 1/4" ~ 2 3/8"

each

42

1 5/8"

495

SOL060

2 1/2" ~ 2 5/8"

each

43~48

1 3/4"~1 7/8"

737

SOL070

2 3/4" ~ 2 7/8"

each

51~54

2"~2 1/8"

1,265

SOL080

3" ~ 3 1/8"

each

55~60

2 1/4"~2 3/8"

1,475

SOL090

3 1/4" ~ 3 3/8"

each

61~68

 2 1/2"~2 5/8"

1,966

SOL100

3 1/2" ~ 3 5/8"

each

69~75

2 3/4"~2 7/8"

2,294

SOL110

3 3/4" ~ 4"

each

76~80

3"~3 1/8"

3,277

Always Store Product in a Cool Dry Place
When stored at 70¡ÆF (
21¡ÆC) or below, the shelf life of product is 18 months. An expiration date is printed on all packaging.
Never use product beyond the expiration date. Storage at higher temperatures may reduce shelf life of product.

81~87

3 1/4"~3 3/8"

3,933

88~93

3 1/2"~3 5/8"

4,920

94~103

 3 3/4"~4"

7,784

NOTE: Socket volumes are approximate and may vary according to manufacturer.

2¢À Packing

Rust-Free Plastic Pails & Sealed Foil Pouches Ensures Product Freshness
Socket Lock's packaging was engineered to protect the product from the harshest conditions such as those found in offshore salt-water environments. We start by packaging resin and hardener in sealed foil pouches to isolate product from environmental factors and ensure product freshness. Kit contents are then placed in rust-free plastic pails to prevent contamination from corrosion commonly found in products that are packed in metal containers.

3¢À Funnels

Many professionals who frequently pour sockets complain of the complications and inconsistency when it comes to pouring the resin into the socket bowl. We listened to your concerns, and developed the patented ¡°Fast Funnel¡± for easy pouring and less mess.
The Fast Funnel is provided with each kit and includes useful information to assist in a good socket pour, and approximate socket resin volumes to minimize waste.

4¢À Features

Newly formulated after extensive testing for better wire rope grip.
Packaged in environmentally protected pouches and rust-free plastic pails to ensure product freshness.
Disposable pouring funnel included in each kit eliminates spills.
Bright green resin and white hardener makes mixing easy to verify.
Packaged in CCs and individually sized kits to minimize waste and aid in easy mixing.
Non-dusting, safe-to-use formula contains no dry powders that become airborne health hazards.

5¢À Technical Specifications

Physical Properties

Standard

Value

Viscosity

ASTM D2196

7,00 - 12,000 centipoise

Density

ASTM D792

1.6 g/cc (.0925 oz/in3)

Linear Curing Shrinkage

ASTM D2566

1.40%

Compressive Strength

ASTM D695

>20,000 psi (138 MPa)

Compressive Modulus

ASTM D695

>1.03 M psi (7,102 MPa)

Compressive Strain

ASTM D695

9.3% at failure

Retention of Compressive Strength After Immersion

ASTM D695

99%+

Barcol Hardness

ASTM D2583

45 - 60

Heat Deflection Temperature

ASTM D648

206¡ÆF (97¡ÆC)

Flexural Strength

ASTM D790

>10,000 psi (69 MPa)

Flexural Modulus

ASTM D790

>1.04 M psi (7,171 MPa)

Flexural Strain

ASTM D790

1.26%

Tensile Strength

ASTM D638

>6,000 psi (41 MPa)

Tensile Modulus

ASTM D638

>1.15 M psi (7,929 MPa)

6¢À Testing

DYNAMICALLY TESTED
Socket Lock's
new and improved formula has been dynamically tested to EN 13411.3 standards, in which socket assemblies were cycled 75,000 times at 30% of the breaking strength of the rope. Following the dynamic testing, assemblies were then break load tested.

SHOCK LOAD TESTED

Large weights were attached to socket assemblies then dropped to prove resin would hold and rope would break.

STATIC BREAK LOAD TESTED

Assemblies up to 3 1/2 inches were destructive tested to verify Socket Lock's performance on high-strength mooring lines. Dynamic and Shock load testing was conducted at Wirop's rigging testing facilities.

Socket-Lock Socketing Resin was tested on a piece of 3.5" EEIPS wire rope used in high-strength mooring applications. The Socket resin successfully held 1.6 million pounds before the rope failed, as it should have, in the undisturbed middle section of the rope. This test further proves that Socket-Lock is a great product to handle harsh conditions.

7¢À How Socket Lock Works

As load is applied to the rope, the resin cone is pulled downward in the bowl of the socket.

As this is happening, the cone shape forces compression of the hardened resin cone against the individual wires and the socket walls.

This compression then generates a tremendous frictional grip between the wires and resin resulting in a strength that exceeds the breaking strength of the rope.

Note:

Some sockets have grooves that may prevent the cured resin cone from seating properly as loading occurs.

Filling the grooves with putty is an acceptable method to correct this situation.

Seating of the cone is necessary to generate compression and frictional forces required to achieve 100% termination efficiency of the assembly.

White Arrows: Friction between resin and wires

Yellow Arrows: Friction between cone and socket wall

Blue Arrow: Load applied to wire rope

8¢À Warnings

Determine if socket has grooves. Inspect inside of socket bowl to determine if socket has grooves.
If grooves are present, fill grooves with socketing putty.

Only use soft annealed iron wire for seizing wire.
Socket Lock resin must be gelled and cured before assembly can be used.
Socket Lock is not to be used with stainless steel rope in a salt water environment.

Never use
oversized sockets for wire rope.
Never use Socket Lock beyond the
expiration date.
Never
heat socket prior to pouring resin in an effort to accelerate the curing of the resin as it may cause the resin to prematurely gel prior to reaching the bottom of the socket bowl.
Doing this could cause the assembly to fail.


Caution
: Exposure to some strong chemicals may affect the cured polymer (hardened resin mixture) in a way that could weaken the assembly. Please contact OH SUNG CO., LTD. e-mail(8965656@hanmail.net), an authorized distributor or the manufacturer if this has occurred.

9¢À Safety Information

When handling the resin or hardener, goggles and protective clothing are recommended.
Impervious gloves are recommended.
Always work in a ventilated area.
Avoid skin or eye contact. Wash skin with soap and water and remove contaminated clothing. If contact with eyes, flush with clean water for at least 15 minutes. If irritation persists, seek medical attention.
Avoid ingestion. If ingestion occurs, DO NOT induce vomiting. Drink milk or water to dilute and call for medical attention.
Avoid inhaling vapors. If excessive vapors are inhaled, move to a fresh air area. If breathing has stopped or is labored seek medical attention.
Never aim an open flame at Socket Lock. Keep away from heat. Resin is a flammable liquid.
Whenever using chemicals, always reference the MSDS sheet for safety and handling guidelines.
NEVER EXCEED THE WORKING LOAD LIMIT OF THE ASSEMBLY

10¢À Temperature and Times

Cold Temperature Issues

In cold temperatures, ideally, the rope, socket and resin would be stored indoors to maintain the components of the assembly at a warmer temperature.
It is best if all three components are the same temperature. Please note that if these three components are stored at room temperature, booster packs should not be used at even the coldest temperatures.

It is not recommended to aggressively apply heat (as with a flame) to the socket prior to pouring since the heat may cause the resin to gel prematurely and prevent the resin from reaching the bottom of the socket cone. Wrapping the socket in a heat blanket to facilitate controlled and uniform heating is a safe and effective method of accelerating the cure process .

NOTE:
Thorough mixing is required to achieve approximate times listed in the table to the right.

Approximate time to gel begins once resin has been mixed.

Approximate time to cure begins once resin has gelled.

WARNING: HEATING SOCKET PRIOR TO POURING MAY CAUSE PREMATURE FAILURE

Ambient

Temperature*

Booster Packs Required

Approximate Gel Time (Working Time)*

Approximate Cure Time (Ready For Service)

¡ÆF

¡ÆC

Packs

Minutes

Minutes

110

43

None

3-4

20

105

41

None

4-6

20

100

38

None

5-6

25

95

35

None

6-8

25

90

32

None

6-8

30

85

29

None

7-8

40

80

27

None

8-9

45

75

24

None

9-10

60

70

21

None

10-12

60

65

18

None

11-13

60

60

16

None

11-13

60

55

13

1

12-14

60

50

10

1

10-12

60

45

7

1

12-15

60

40

4

1

20-22

90

35

2

1

25-35

90-120

30

-1

1

35-45

120

*NOTE: Times are approximate. The temperature of the resin, socket and wire rope can affect these times. The times above are based on the resin being at conditioned at room temperature (70F – 21C) and the socket and wire rope being at the ambient temperature indicated.

11¢À Socketing Procedures

STEP 1
Measure Socket Bowl
To determine where to apply seizing wire, measure socket from bottom of socket to the top of the bowl.

The end of the rope should be long enough so the ends of the wires after being broomed will be at or slightly below the top of the socket bowl.

STEP 2

STEP 3
Apply Seizing Wire at Base of Socket

Apply the seizing wire one (1) socket bowl length from the rope end and continue to apply, working away from the rope end. The seizing length must be at least two (2) rope diameters long. Additional information is available from the Wire Rope Users Manual, Wire Rope Manufacturer's Catalogues or National Standards.

Plastic coated, plastic filled wire ropes and fiber cored ropes must have all plastic material and nonmetallic materials removed from within the broomed area.

NOTE: Only use soft annealed iron wire for seizing wire.

STEP 4
Broom Wire Rope End


Using a marlin spike, begin to open the strands.


Using a short piece of pipe, bend each strand open to a 60 degree included angle.


Open strands evenly as shown here. Should the rope have a plastic coated core, remove all plastic coating. For fiber core ropes, cut out the fiber core.


Poorly Broomed


Poorly Broomed

Keys to Making a Good Socket Pour
 As tension is applied to a finished socket assembly, friction between the hardened resin and wires must exceed the friction between the outside of the resin cone and inner socket wall preventing the wires from pullingout, and allowing for the resin cone to seat and compress. The compression that is then generated between the wires and resin cone becomes stronger than the wire rope itself. For proper friction to occur, it is very important that the rope end be properly broomed and opened all the way down to the seizing to allow resin to reach the bottom of the socket bowl. See illustration below.

Thoroughly cleaned wires provide greater adhesion; therefore, providing more friction that helps enable properseating of the  resin cone and generating compression to provide the required strength of the assembly.

A socket assembly that was properly aligned during the pouring of the socket will allow for even distribution of forces on the wire and resin cone; therefore, possessing strength greater than the wire rope. If the rope is not properly aligned while pouring of the resin into the socket, the rope will be set at an angle. Testing has shown that when this occurs, the rope will break at the base of the socket below the catalog breaking strength of the rope.
 

STEP 5

Clean Wire Rope End

Swish the broomed-out rope end in a solvent and make sure that the wires are clean from the very bottom of the broom up to the seizing band. After cleaning, place the broomed-out rope end pointing downward. Allowing it to remain inverted until all solvent has evaporated and the wires are dry. Solvent should never be permitted to remain on the rope or on the serving band since it will run down the wires when the rope is turned upright.


NOTE: Clean solvent is recommended to achieve best results.

STEP 6

Pull Broom Into Socket Bowl Pull the socket up over the rope broom.
Make sure the rope wires are uniformly spaced in the socket bowl, with the wire ends slightly below the top edge of the bowl and the axis of the rope and the socket are aligned.

The top of the seizing should be even with the bottom of the socket.
Be sure not to allow any broomed wire to extend below the base of the socket.

STEP 7

Seal Bottom of Socket Wrap the bottom of the socket with socketing putty, being sure to press the putty into the valleys between the strands.
To provide a greater seal, wrap electrical tape over the socketing putty.

STEP 8
Mix Resin
Knead resin pouch for approximately 30 seconds prior to cutting open to mix the resin/silica thoroughly. Cut open the resin pouch and squeeze contents into mixing container provided.
Cut open the hardener pouch and squeeze contents into resin.
With a mixing paddle, thoroughly mix resin and hardener until color is uniform, then continue mixing for 30 seconds to ensure complete mixing.

STEP 9

Pour Resin Mixture Into Socket
After mixing resin and hardener, immediately prepare to pour it into the socket.

Position the provided ¡°Fast Funnel¡± so that the resin will discharge out of the funnel into the socket bowl along the socket wall. This will help the resin reach the bottom of the bowl and reduce chance of trapping air.
Fill to the top edge of the socket bowl. As resin mixture penetrates down into the bowl, it may be required to add more resin to the socket bowl. Never add more resin to the bowl after resin has begun to gel and harden.

Allow resin to firmly gel prior to moving assembly. Prematurely moving the assembly could damage the resin before it hardens; therefore, reducing the efficiency of the termination. Wait 10 to 15 minutes after the resin has gelled before moving the assembly. Please refer to Page 11 of this document for approximate gel times.

When recommended procedures are followed and resin has been allowed to fully cure, socket assemblies prepared with Socket Lock resin will attain 100% Termination Efficiency

STEP 10

Re-Lubricate Wire Rope

After the resin has cured, re-lubricate the wire rope to replace any lubricant that may have been removed during the cleaning process.

STEP 11

Proof Test Assembly (Recommended) It is recommended to proof load the assembly to twice the safe working load prior to putting the assembly into service per ASME B30.9.

¢À Renference : sea-fit, inc.(U.S.A)
¢À Please feel free to call: 02-896-5656 or Fax: 02-896-5659 or contact us via e-mail(8965656@hanmail.net) so our company can help you obtain the correct equipment for your applications.

 